beautypg.com

Electrical installation, Electrical connections; fig. 1 – American Standard Selectronic 195 User Manual

Page 5

background image

Fig. 1e

8

10

ELECTRICAL INSTALLATION

M 9 6 5 2 74

4

Fig. 1

Fig. 1b

1. Remove ENCLOSURE COVER (1). Fig. 1.

2. Feed the WIRE CONNECTORS (2) through the top
of ENCLOSURE

(5). Fig. 1a.

3. Remove GROMMET (4) from ENCLOSURE (5). Fig. 1.

4. Feed the gray SENSOR WIRE (7) through
GROMMET

(4), 4" from CONNECTOR. Fig. 1b. Insert

gray SENSOR WIRE

(7) into SPLIT PLUG (9). Push

SPLIT PLUG

(9) into GROMMET (4) to seal. Fig. 1d.

5. Insert GROMMET (4) back into ENCLOSURE (5).
Fig. 1c.

6. Install CIRCUIT BOARD (3) into ENCLOSURE (5)
with SENSOR WIRE

(7) under BOARD. Fig. 1c.

7. Insert SENSOR WIRE CONNECTOR (8) and
EXTENSION WIRE CONNECTOR

(11) into available

CIRCUIT BOARD RECEPTORS

(10) slots. Fig. 1e.

8. Connect wires from SENSOR to SOLENOID VALVE
(6) (Red to +, Black to -). Fig. 1d.

9. Replace ENCLOSURE COVER (1). Tighten cover
screws firmly.

10. Contractor to supply ELECTRICAL BOX (12)
and connection to ENCLOSURE (5).
Mount POWER
SUPPLY

(13) into ELECTRICAL BOX (12). Connect

White and Black power connections to POWER
SUPPLY CABLE

(14). Fig. 1f.

11. Connect the EXTENSION WIRE (16) to the
POWER SUPPLY CABLE

(15). FIG. 1f.

ELECTRICAL CONNECTIONS; Fig. 1

1

4

8

RED

6

Fig. 1c

Fig. 1d

7

4

9

1

4

7

5

4

4"

3

CAUTION

Before opening ENCLOSURE

disconnect AC power supply.

BLACK

F

5

2

Fig. 1a

5

7

10
11

Fig. 1f

BLACK & WHITE

POWER

CONNECTIONS

15

13

CONNECTOR NOT

USED IN THIS

INSTALLATION

16

14

4" ELECTRICAL BOX

OR EQUIVALENT BY

OTHERS

12

This manual is related to the following products: