beautypg.com

Mount enclosure; fig. 2 – American Standard Selectronic 195 User Manual

Page 4

background image

Fig. 2

1. Determine location of ENCLOSURE (1). It must be
located with-in the 14" (356mm) by 21" (533mm)
shaded area shown in

Figure 2 in order for electrical

connections from the spout assembly to be made.
NOTE: ENCLOSURE SUPPLY HOSE is 20". Distance
between wall supply and ENCLOSURE (1) must be
taken into consideration.

2. Remove 4 screws from COVER (2) and pull off
COVER

(2). Hold the ENCLOSURE (1) in desired

location and mark the four mounting hole locations as
shown.

Fig. 2.

3. The ENCLOSURE (1) works best if secured to a wall
stud or cross brace within the wall, using the SCREWS
(3) supplied. If the ENCLOSURE (1) is to be installed on
a tile or plaster wall the ANCHORS

(4) and SCREWS

(3) should be used.

4. For installations on drywall or tiled walls; use
ANCHORS

(4) and SCREWS (3) for securing

ENCLOSURE

(1) to finished wall. Drill four 1/4" dia.

holes a minimum of 1-3/4" deep. Insert the four
ANCHORS

(4) flush with face of the finished wall.

Align the ENCLOSURE

(1) and Install the MOUNTING

SCREWS

(3). Tighten to secure ENCLOSURE (1) to

mounting surface.

14"

(356mm)

3-3/4"

(96mm)

2-3/4"

(71mm)

3"

(76mm)

21"

(mm)

2

4

3

1

1

1

20"

(500mm)

MOUNTING HOLES

SUPPLIES

WASTE

ENCLOSURE

MOUNTING

HOLES

LAVATORY RIM OR

MOUNTING SURFACE

3

NOTE: If using Mixing Valve (optional) See Sheet
#M968808 for installation instructions.

MOUNT ENCLOSURE; Fig. 2

2

1. Connect SUPPLY NUT (1) from spout assembly to
nipple on top of ENCLOSURE

(2). Tighten with

adjustable wrench to make a water tight connection.
Fig. 3.

NOTE; If using the optional Mixing Valve See Sheet
#M968808 for installation instructions.

CONNECT SPOUT HOSE TO

ENCLOSURE; Fig. 3

CONNECT WATER SUPPLY TO

ENCLOSURE AND WALL SUPPLY;

Fig. 4

3

Fig. 3

4

1

2

1

3

3

Fig. 4

2

1. Insert FIBER WASHER (4) into SUPPLY NUT (1) on
ENCLOSURE

(2).

2. Connect SUPPLY NUT (1) on ENCLOSURE (2) to
FLEXIBLE SUPPLY HOSE

(3). Tighten to make a

water tight connection. Use two wrenches to tighten if
necessary.

Fig. 4.

3. Connect FLEXIBLE SUPPLY (3) directly to wall supply.

Connection on FLEXIBLE SUPPLY

(3) is 3/8"

compression. Use adjustable wrench to tighten

connection. Do not over tighten.

Fig. 4a.

Note: FLEXIBLE SUPPLY (3) measures 20" from the

bottom of the ENCLOSURE

(1) base. If additional

supply length is required, installer must purchase parts

separately.

Important: If FLEXIBLE SUPPLY (3) is too long, loop to

avoid kinking.

COLD WATER OR

TEMPERED

WALL SUPPLY

4

Fig. 4a

DO NOT USE PIPE

SEALANT ON THREADS

M 9 6 5 2 74

4" ELECTRICAL BOX

OR EQUIVALENT BY

OTHERS