INSTALLATION

SSPE14: Floor Model Electric Pasta Cooker

5 L20-339, rev.02 (08/11)

1.5. ELECTRICAL

CONNECTIONS

It is advised that this power supply be plugged into a wall receptacle that is controlled by the ventilation control. This
will prevent the appliance from being operated without the ventilator on. If your appliance requires an electrical
connection, the power requirements are listed below.

WARNING

All copper wiring for this appliance must be made in accordance with the wiring

diagram(s) located on the appliance.

CAUTION

Connecting the appliance to the wrong power supply

may damage the appliance and void the warranty.

WARNING

Stationary appliances not fitted with means for disconnection from the supply mains having a

contact separation in all poles that provide full disconnection under overvoltage category III, the

instructions state that means for disconnection must be incorporated in the fixed wiring in

accordance with the wiring rules.

WARNING

This appliance must be connected to a power supply having the same voltage and phase as

specified on the data plate located on the inside of the appliance door.

WARNING

DO NOT attempt to connect the appliance to an electrical supply other then that indicated

on the data plate. Electrical connection should be performed by qualified personnel.

WARNING

The appliance must be grounded in accordance with local code; if there is no local code,

comply with the NEC and ANSI/NFPA No. 70 latest edition (for US and Canadian

installations). In all other cases, refer to local and national codes and regulations. To

comply with European requirements, European models are equipped with an equalization-

bonding clamp. An equalization bonding lead must be connected to this clamp to provide

sufficient protection against potential difference. This clamp, located on the rear of the

appliance is marked with the following universal symbol.

VOLTAGE (VAC)

PHASE (Ø)

POWER (kW)

Current (A)

200

11.6

58

208

12.5

60

220

11.4

52

240

12.5

52

200

11.6

33

208

12.5

35

220

11.4

30

240

12.5

30

346/200

11.6

19

380/220

11.4

17

400/230

12.5

18

415/240

12.5

17

Electric Power Supply Table

Single (1)

Three (3, Delta)

Three

(3/+ Neutral)

(WYE)