INSTALLATION
SSPE14: Floor Model Electric Pasta Cooker
5 L20-339, rev.02 (08/11)
1.5. ELECTRICAL
CONNECTIONS
It is advised that this power supply be plugged into a wall receptacle that is controlled by the ventilation control. This
will prevent the appliance from being operated without the ventilator on. If your appliance requires an electrical
connection, the power requirements are listed below.
WARNING
All copper wiring for this appliance must be made in accordance with the wiring
diagram(s) located on the appliance.
CAUTION
Connecting the appliance to the wrong power supply
may damage the appliance and void the warranty.
WARNING
Stationary appliances not fitted with means for disconnection from the supply mains having a
contact separation in all poles that provide full disconnection under overvoltage category III, the
instructions state that means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.
WARNING
This appliance must be connected to a power supply having the same voltage and phase as
specified on the data plate located on the inside of the appliance door.
WARNING
DO NOT attempt to connect the appliance to an electrical supply other then that indicated
on the data plate. Electrical connection should be performed by qualified personnel.
WARNING
The appliance must be grounded in accordance with local code; if there is no local code,
comply with the NEC and ANSI/NFPA No. 70 latest edition (for US and Canadian
installations). In all other cases, refer to local and national codes and regulations. To
comply with European requirements, European models are equipped with an equalization-
bonding clamp. An equalization bonding lead must be connected to this clamp to provide
sufficient protection against potential difference. This clamp, located on the rear of the
appliance is marked with the following universal symbol.
VOLTAGE (VAC)
PHASE (Ø)
POWER (kW)
Current (A)
200
11.6
58
208
12.5
60
220
11.4
52
240
12.5
52
200
11.6
33
208
12.5
35
220
11.4
30
240
12.5
30
346/200
11.6
19
380/220
11.4
17
400/230
12.5
18
415/240
12.5
17
Electric Power Supply Table
Single (1)
Three (3, Delta)
Three
(3/+ Neutral)
(WYE)