PREVENTATIVE MAINTENANCE
L20-339, rev.02 (08/11)
14
WARNING
The power supply must be disconnected before cleaning and servicing this appliance!
3.3. ANNUAL/PERIODIC
PREVENTATIVE MAINTENANCE AND INSPECTION
This section should ONLY be performed by a qualified service technician as part of a regular kitchen maintenance
program. This inspection should take place a minimum of once a year by an Authorized Service Technician
recommended by Pitco. It may be necessary perform this inspection more then once a year.
3.3.1. HEATING
ELEMENT
Check if the element is mechanically strong and in good condition. Look for scale build up and inspect for
signs of repeated dry firing.
Verify element wires are in good working condition. Look for damage to wires or frayed insulation. Check
that the insulation is dry.
Verify that bulkhead connections/nuts are tight and leak free. Look for water stains and wet surfaces.
Verify amp-draw is within range as compared to the information on the data plate.
3.3.2. TEMPERATURE PROBE & HIGH LIMIT PROBE
Verify probes are in good working condition. Check for damage and that the fasteners are tightly secured to
the tank.
Verify compression fittings are leak free.
Check wiring for loose electrical connections.
3.3.3. CONTROLLER
Refer to controls operation manual to check all control functions.
Verify that the controller is in good mechanical condition. Check all lights, displays and buttons to assure that
they are working properly. Examine overlay for damage that could allow moisture to enter.
Check for loose electrical connections.
Verify simmer temperature. Check temperature 1” above controller probe, if necessary check probe
resistance.
Check drain valve interlock to ensure that the appliance stops heating when the drain valve is open.
3.3.4. CONTROL BOX & ELECTRICAL COMPONENTS
Verify that heating contactors are in good condition. Check for worn or pitted contacts. Verify that wires are
tight and in good condition.
Verify that all components (transformer, terminal block, relays, drain switches, etc.) are in good condition.
Verify that wires are tight and in good condition.
Verify enclosures are free of leaks. Check for water stains and wet surfaces.
Verify that the covers and panels are in tact and provide a safe condition. Check for loose parts.
Verify power cord is in good condition. Check for frayed or exposed wires. Verify that the insulation is in
good condition and the attachment to the appliance is tight.
3.3.5. TANK & DRAIN SYSTEM
Verify that the tank is in good condition. Check for scale build up and inspect for signs of corrosion. Verify
that tank is leak free. Check drain overflow for scale build up and debris blockage.
Verify that drain valve is in good condition. Check for leaks in the seal area and fitting region.
Verify that drain lines are leak free, kink free and in good condition. Check for scale build up and debris
blockage. Verify that the clamps and connections are securely tightened.