beautypg.com

Pitco Frialator Gas Pasta Cookers PG14D User Manual

Page 34

background image

3-2

a.

A fuse is located in a batonet type fuse holder located on bottom of the cabinet header.

b.

Remove the fuse from its holder by pushing in and turning 1/2 turn counter clockwise.

c.

Use an ohmmeter set on "x 1" ohms (resistance) setting to check the fuses for continuity. For
a GOOD fuse, the meter reading should be approximately zero "0" ohms. If the reading is
significantly above zero ohms, replace the fuse.

d.

Replace each fuse and ensure that it is secured in its fuse holder.

e.

Call a qualified technician if fuses continually blow.

3.3

Maintenance

NOTICE

A cooker that has casters will have a quick disconnect gas connection
and a restraining device. Care should be exercised when moving the
cooker out from the wall to be serviced. When moving the cooker
back into place, ensure that the restraining device is connected
properly. Be careful not to kink the gas hose.

3.3.1 Flue And Baffle Inspection

It is recommended that once every six months, with the cooker cooled down, the flue area be
examined. Check for corrosion or blockage of the flue. Ensure that the cooker is shut down and do
not turn the cooker on during the examination.

WARNING

Examination of the flue area during cooker operation may cause
bodily injury.

This manual is related to the following products: