beautypg.com

Pitco Frialator Gas Pasta Cookers PG14D User Manual

Page 15

background image

1-5

WARNING

DO NOT supply the cooker with a gas that is not indicated on the data
plate. Using the incorrect gas type will cause improper operation. If
you need to convert the cooker to another type of fuel, contact your
dealer.

1.3.3.1 Fuel Types

Each Pasta cooker is equipped to work with one type of fuel. The type of fuel with which the appliance
is intended to operate is stamped on the data plate attached to the inside of the cooking and warming
section door.

WARNING

DO NOT use an open flame to check for gas leaks!

1.3.3.2 Fuel Supply Line Leak and Pressure Testing

The fuel supply system must be tested before the cooker is used. If the fuel line is going to be tested
at a pressure greater than (>)1/2 PSIG (3.45 kPa), make sure that the cooker is disconnected from the
fuel line. If the fuel line is to be tested at a pressure equal to or less than (<) 1/2 PSIG (3.45 kPa),
the cooker can be connected but the cooker's gas valve must be shut. Test all gas line connections
for leaks with a solution of soap and water when pressure is applied.

NOTICE

NEVER use an adaptor to make a smaller gas supply line fit the cooker
connection. This may not allow proper gas flow for optimum burner
operation resulting in poor cooker performance. NEVER supply the
cooker with any fuel other than the type indicated on the data plate.
Using the wrong type gas will cause improper operation.