Nor-Lake NL708 Door Alarm User Manual
Page 17
Operating Instructions Alarm/Light Module XWA11V
01/14 Rev F. 142498
Page
16
The factory setting (Normal) is suitable for most applications, but it may be necessary to adjust the PIR
sensitivity if there is any environmental interference causing false triggers or if sensitivity needs to be
increased for your particular application. Use DIP switches 1 & 2 to adjust sensitivity.
Sensitivity
Settings
1
2
High
Normal
X
Medium
X
Low
X
X
ON Time Timer (Switches 3 – 7)
Use DIP switches 3 to 7 to adjust the ON time duration. Note: will restart timer every time motion it detected.
Timer Settings
Settings
3 4 5 6 7
15 Seconds
X X X X X
5 Minutes
X X X X
10 Minutes
X X X
15 Minutes
X X
20 Minutes
X
30 Minutes
Override (Switch 8)
The override disables the occupancy control feature of the sensor module. When occupancy control is
disabled, the load remains ON as long as the sensor is powered.
Override
Settings
8
9
10
OFF
n/a n/a
ON
X n/a n/a
Please mark your current settings for reference.
Date: 1 2 3 4 5 6 7 8
9
10
n/a
n/a
n/a
n/a
Remote Buzzer Box Installation
Note: The sensor is pre-set at
the factory to meet the
requirements of most
applications. Sensor factory
pre-sets are bold. “X”
indicates switch in the ON
position.