Merrychef eikon e6 User Manual
Page 55
E2 SERVICE MANUAL REV D 09/12
55
11
10
4
9
8
7
5
3
2
1
20
24
25
14
15
19
SRB Terminal Locations:
1
X3 - Output for e2 Convection Fan
Controller.
2
X101 - Voltage Selection Relay coil
feeds.
3
X18b – Air Intake Filter Reed (Jumper)
4
X18e – Right Magnetron Thermostat
(Jumper)
5
X18d - Magnetron Thermostat (Top).
6
X18c - Cavity Overheat Thermostat
7
X18a - On/Off Switch
8
X14 - Cavity Temperature
Thermocouple
9
X5 - Fan RPM Input
10
X13 - P Bus, Ethernet Port
11
X12 - C Bus, Development PC Port
12
X11 - P/C Bus, QTS Cable
13
X1 - 24V supply from Low Voltage
Transformer
14
X8 - Cooling Fan
15
X17 - Not used.
16
X20 - Microwave Stirrer(s)
17
X9 - Mains Output, Convection Fan
Controller.
18
X103.1 - Mains Output to Low Voltage
Transformer.
19
X103 - Mains Input, Live & Neutral.
20
X2.1 - Mains Input, Live for Heaters.
21
X2.2 - Mains Output, Live to Heaters.
22
X102a - Mains Input, Neutral for
Magnetron Transformers & Monitor
Door Switch.
23
X102b - Mains Output, Neutral to
Magnetron Transformers & Monitor
Door Switch
24
X4a - Door Switch signal from
Secondary Door Switch (Live for
Magnetron Transformers)
25
X10 - Connector Block for door
switches
26
X4b - Live for Magnetron Transformers