Merrychef eikon e6 User Manual
Page 49
![background image](/manuals/458878/49/background.png)
E2 SERVICE MANUAL REV D 09/12
49
Error
Code
Oven
Error/Event
Condition
Description
Trigger
Error
Level
System
Response
E108
All
QTS PM error
Wrong QTS PM
found / no QTS
PM found
The QTS has an
incorrect PM
(personality
module) installed
or no PM is
installed
Critical
“E108 QTS PM
FAILED"
message is
displayed on the
screen.
Thi
i
E109
All
SRB PM error
Wrong SRB PM
found / no SRB
PM found
The SRB has an
incorrect PM
(personality
module) installed
or no PM is
installed
Critical
“E109 SRB PM
FAILED"
message is
displayed on the
screen.
Thi
i
t
E110
All
Incompatible SRB
software version
SRB firmware
version is
incompatible with
the SRB
The SRB has
found that the
firmware running
the SRB is not
supported.
Critical
This error is not
recorded in the
error log.
"E110 SRB
VERSION
CONFLICT"
E3, E4, E5
SRB firmware
version is
incompatible with
the QTS version
The QTS has
found that the
firmware running
the SRB is not
supported.
E111
All
Cavity sensor error
The cavity
temperature
sensor is no
longer operating
The SRB is
reading an open or
shorted
thermocouple input
Critical
"E111 CAVITY
SENSOR"
message is
displayed in the
error log.
"E111 CAVITY
E112
E3, E4, E5
SRB board sensor
failed
The temperature
sensor on the
SRB board is no
longer operating
The SRB is
reading an open or
shorted sensor
mounted on the
board
Critical
"E112 CAVITY
SENSOR
CIRCUIT
FAILED"
message is
displayed in the
E2, E6
"E112 SRB
AMBIENT
SENSOR
CIRCUIT
FAILED"
message is
E113
All
Magnetron On without
request
Magnetron failed
to turn OFF
The magnetron
current measured
by the SRB was
outside of the
tolerance range
Critical
"E113
MAGNETRON
ON WITHOUT
REQUEST"
message is
written to the