41
(Personality Module) Replacement
The PM on the SRB contains the
Firmware. The PM on the QTS
contains the Firmware, Oven Serial
Number, Temperature Calibration,
Cooking Programs, Application Icons
and the Recipe Images
.
1 With a new PM fitted and casing refitted,
switch on the oven and tap the screen to
hold and check the QTS and SRB
versions (1) are the latest release, if not,
execute a Firmware update using the
latest versions. For details see ‘Firmware
Updates’ (Servicing section).
2 Tap the top right of the screen to bypass
the preheat stage (2).
3 Enter the manager password and select
OK to display the Settings menu, see (3).
4 Select the USB symbol (4).
5 Slide the Merrychef badge upwards and
insert the USB Memory Stick into the slot
(5).
6 Once the oven has recognized the USB
device, select the required USB symbol
(6).
7 Select the Application Icons file to
download (7). Note; a tinted band over a
file name indicates the file is not valid for
that oven.
8 Check the file information shown is
correct before selecting OK (8), if not,
select ‘X’ and locate the correct file.
9 When completed, select recipes to load
the cooking programs (9). Once the
programs are loaded the oven restarts.
10 Enter the Date & Time settings (10). For
details see under ‘Oven Control Settings’
(Product Information section).
11 Turn the oven switch OFF/ON.
12 Remove the USB and keep in a safe
place. Reposition the USB cover.
1
2
3
4
5
6
7
8
9
10