Features in 276-04
6
Version 276-05
C613-10474-00 REV D
Features in 276-04
Software Maintenance Version 276-04 includes all resolved issues and enhancements in earlier versions, and the resolved issues and enhancements in the
following tables. In the tables, for each product series:
■
“Y” in a white column indicates that the resolution is available in Version 276-04 for that product series.
■
“-” in a white column indicates that the issue did not apply to that product series.
■
a grey-shaded column indicates that Version 276-04 was not released on that product series.
“-” in a grey column indicates that the issue did not apply to that product series.
“Y” in a grey column indicates that the issue applied to that product series. These issues are resolved in the next Version (276-05).
Level 1
CR
Module
Level
Description
AR
44xS/
AR4
50S
AR
7x5
AR
750S
Ra
p
ier
i
A
T-
8
800
A
T-
8
600
A
T-
8
700XL
A
T-
8
948
A
T-
9
900
A
T-
9
800
CR00007273
Switch
1
If a user created a configuration file that contained port trunk settings before
VLAN port settings, then a loop occurred when the switch rebooted with this
configuration.
This issue has been resolved.
-
-
-
Y
Y
Y
Y
-
-
-
CR00011711
PIM v6
1
For IPv6, the router or switch could restart when PIM-SM detected that the
primary RPF interface to an (S,G) routing entry had changed because the RPF
interface had gone down. When the interface went down, PIM-SM recalculated
the RPF to the source for the (S,G) entry, and if PIM-SM only found a non-PIM
neighbour as the RPF to the source for the (S,G), the router or switch could
restart.
This issue has been resolved.
Y
-
Y
Y
Y
-
-
-
-
-