Features in 276-04
16
Version 276-05
C613-10474-00 REV D
CR00012952
Bridge
2
If a tagged packet was bridged out of a VLAN interface, the interface always
added a VLAN tag into the packet, even though the packet was already tagged.
This issue has been resolved.
Y
-
Y
-
-
-
-
-
-
-
CR00012991
ATM
2
The maximum allowed value of the vpi parameter in the commands add and set
atm channel has been increased from 8 to 15.
Y
-
-
-
-
-
-
-
-
-
CR00013023
OSPF
2
An issue occurred when OSPF was configured to create passive interfaces by
default (set ospf passiveinterfacedefault=on) but an OSPF interface was not
passive (set ospf interface=interface passive=off). This interface setting was
saved in the configuration file or output resulting from the commands create
config and show config dynamic, but any other changes to interface settings
were not saved (such as changes to authentication settings). If the router or
switch rebooted, these other interface changes were lost.
This issue has been resolved.
Y
-
Y
Y
Y
Y
Y
-
-
-
CR00013077
IPv6
2
When an IPv6 address was deleted on the router or switch, and that IPv6 address
had previously been learnt by a remote IPv6 node, then the router or switch
would reboot if it received an ICMPv6 Neighbour Solicitation message from the
remote node. This meant, for example, that if you successfully pinged an address
on the router or switch, then deleted that address, then attempted to ping the
old address again, the router or switch would reboot.
This issue has been resolved.
Y
-
Y
Y
Y
-
-
-
-
-
CR00013081
Switch, STP
2
When STP was enabled on ports in a trunk group, the non-master ports did not
have the same state as the master port in the switch’s hardware STG table. This
could, on rare occasions, create a broadcast storm.
This issue has been resolved. All ports in a trunk group follow the master port in
the hardware STG table.
-
-
-
Y
Y
Y
Y
-
-
-
CR