Allied Telesis AR44xS series User Manual
Page 57

Features in 276-01
57
Version 276-05
C613-10474-00 REV D
CR00010896
Switch
2
AT-40/SC, AT-40/MT and AT-41/MT uplink modules would stay link down when
they were set to a fixed speed.
This issue has been resolved.
-
-
-
Y
-
-
Y
-
-
-
CR00010996
Port
Authentication
2
When port authentication was using a RADIUS server, it sometimes stopped
working after several hours. This was because port authentication generated
RADIUS Accounting Request (STOP) messages with an incorrect Acct-Session-
Time value.
This issue has been resolved.
Y
Y
Y
Y
Y
Y
Y
Y
Y
-
CR00011040
Ping
2
When the router or switch was configured with multiple logical interfaces, it
chose the source address of the ICMP Echo Reply incorrectly in some
configurations.
This issue has been resolved.
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
CR00011068
SSL
2
Previously, there was a memory corruption issue in the SSL client and server
implementation.
This issue has been resolved.
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
CR00011111
IPX
2
Forwarding an 802.3 or ETHII encapsulated IPX packet over a VLAN to a remote
network occasionally caused the switch to reboot.
This issue has been resolved.
-
-
-
Y
Y
Y
Y
Y
Y
Y
CR
Module
Level
Description
AR44x
S /
AR4
50S
AR
7
x
5
A
R
7
50S
Ra
p
ie
r i
A
T
-880
0
A
T
-860
0
A
T
-870
0X
L
A
T
-894
8
A
T
-990
0
A
T
-980
0