Features in 276-04
19
Version 276-05
C613-10474-00 REV D
Level 3
CR
Module
Level
Description
AR
44xS/
AR4
50S
AR
7x5
AR
750S
Ra
p
ier
i
A
T-
8
800
A
T-
8
600
A
T-
8
700XL
A
T-
8
948
A
T-
9
900
A
T-
9
800
CR00008192
Switch
3
The following issues occurred with the counters that are displayed by the show
interface=port-number counter command:
■
If a switch port received a broadcast or multicast packet with an error (such as
a bad CRC error), the ifInUcastPkts counter—the number of unicast packets
received— was incremented. This issue has been resolved.
■
On AT-9800 series switches, the ifInErrorOctets counter is a count of packets,
not octets. Therefore, this counter has been renamed to ifInErrors.
-
-
-
Y
Y
Y
Y
-
-
-
CR00010345
Firewall
3
When the HTTP proxy URL filter had entries that allowed certain domains and
also had entries that denied certain keywords, the supposedly-allowed domains
were denied if they contained the denied keywords. The proxy allowed the page
/index.html from such domains, but no other pages.
This issue has been resolved. The proxy no longer checks allowed domains
against the keyword list.
Y
-
Y
Y
Y
-
-
-
-
-
CR00010504
IP Gateway
3
When a VRRP master was configured with VRRP adoption enabled, pings from
the VRRP master to its own VR IP address failed.
This issue has been resolved.
Y
-
Y
Y
Y
Y
Y
-
-
-
CR00011444
Asyn
3
If information was sent to a console (asyn) port that had no cable plugged into
it, excessive CPU usage occurred.
This issue has been resolved.
Y
-
Y
Y
Y
Y
Y
-
-
-