beautypg.com

Operation of infinity series whirlpools – Aquatic Infinity Series User Manual

Page 16

background image

AQUATIC INDUSTRIES, INC.

17

INFINITY AIR BATH CONTROL (SEE DIAGRAM 6C):

1. To Turn Air Bath System On: Pressing the On/Off

button will turn the blower on in “constant mode.” Once
the blower is on, pressing a second time will turn the
blower off. The light indicator will illuminate when the
system is on. The blower and the blower heater will
automatically shut off after a 20-minute period.

2. To Change Modes: Pressing the Mode button

alternates the blower modes of operation from constant
mode to wave mode and then to pulse mode.

Constant Mode:

Consists of a constant blower level with no change. The light indicator will

also follow the blower intensity set by the user.

Wave Mode:

Consists of a gradual change of blower level to generate a gentle massage effect.

The light indicator will also follow the blower intensity.

Pulse Mode:

Consists of an instant change of the blower level to generate a massage effect.

The light indicator will also pulse as the blower does.

OPERATION of

INFINITY SERIES WHIRLPOOLS

INFINITY JET SEQUENCER CONTROL (SEE DIAGRAM 6B):

1. To Turn Jet Sequencer On: Pressing the “On/Off” button will turn the jet sequencer on. The system

will then perform an indicator light test and open all valves. Pressing the “On/Off” button a second
time will turn the jet sequencer off. A built-in timer automatically turns the jet sequencer off after
2 hours, unless manually deactivated first. Note: Pump must be turned on for the jet sequencer
to be effective (see “Infinity On/Off with Heater Control” above.)

2. To Choose Sequences: Press the “Sequences” button

to select one of the 7 preprogrammed massage
sequences. Note: Only the first 6 sequences have
corresponding indicator lights. The remaining sequences
do not have indicator lights. A preview of the massage
is displayed for 5 seconds after selecting a sequence.

3. To Change Speeds: Press the “Speeds” button to

change the time interval between each step of the
selected massage sequence.
Speed 1:

15 Seconds between each step.

Speed 2:

10 Seconds between each step.

Speed 3:

5 Seconds between each step.

4. To Pause: Press the “Pause” button to interrupt a massage sequence and prolong the action of a

jet set for a combination of sets. Pressing a second time will resume the massage sequence. The
“Pause” indicator light will be on in “Pause” mode.

Other Features:

Automatic purge:

Thirty minutes after the jet sequencer has shut off, the solenoids will open and close

to drain any water from the pipes.

BATHSIDE CONTROL SYSTEMS (continued):

6C

6B