beautypg.com

Installation instructions – Aquatic Infinity Series User Manual

Page 12

background image

AQUATIC INDUSTRIES, INC.

13

PLEASE SEE DIAGRAMS 4A AND 4B. (PAGE 14)

BONDING WIRE:

Connect a #8 bare copper bonding wire from the pump motor to the heater

and then to the cold water plumbing or other suitable ground. Grounding is required.

For built-in and custom units, install to permit access for servicing.

BREAKER PANEL

15 AMP

2 POLE

GFCI

BREAKER

15 AMP

1 POLE

GFCI BREAKER

BLOWER

MAIN

HEATER

WHITE

RED

BLACK

GROUND

WHITE

BLACK

GROUND

INSTALLATION INSTRUCTIONS

ELECTRICAL INSTALLATION (continued):