INSTALLATION INSTRUCTIONS

WARNING:

ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LICENSED, LOCALLY CERTIFIED

ELECTRICIAN, IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODES AND
PROCEDURES.

WARNING:

WHEN USING ELECTRICAL PRODUCTS, PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,

INCLUDING THE FOLLOWING:

DANGER: RISK OF ELECTRIC SHOCK!

GFCI’s are not supplied, however we do specify their use.

All known code authorities require GFCI’s.

The Infinity I - VIII

will need to be hard wired to the outlets provided. See the following directions and diagram.

Two junction boxes will be mounted to the frame of the whirlpool. One of the two boxes will have one outlet
and will be labeled “Blower”. Remove the cover and connect a 14/2 with ground Romex wire from a 15 amp
1-pole GFCI breaker (not supplied) in the main circuit breaker panel. Connect the black wire to the hot side
of the receptacle, the white wire to the neutral side of the receptacle and the green wire to ground. Replace
the cover and plug in the blower. (See diagram on page 13).

The second junction box will have two outlets, one labeled “Main” and the other labeled “Heater”. Remove
the cover. Run Romex 14/3 with ground from a 15 amp 2-pole GFCI breaker (not supplied) located in the breaker
panel. Connect the white wire (neutral) to both neutrals of the two outlets. Connect the red wire (hot) to the
hot terminal of the outlet labeled “Main”. Connect the black wire (hot) to the hot terminal of the other outlet
labeled “Heater”. Connect the green wire (ground) to the ground terminal of the outlet. Replace the cover of
the junction box. Find the cord labeled “Heater AC Input” and plug it into the outlet labeled “Heater”. Plug
the cord labeled “Main AC Input” into the outlet labeled “Main”. Both of these cords will come from the right
side of the heater and will be marked. (See diagram on page 13).

CONTINUOUS WATERFALL (INFINITY I):

The Infinity I is equipped with a continuous waterfall that is powered by a recirculation pump. The recirculation
pump is plugged into your maintenance heater (see Diagram 4A, pg. 14). The maintenance heater must be
plugged in for the continuous waterfall to be operational (see Diagram 4A, page 14). See page 16 for
operation instructions.

ELECTRICAL INSTALLATION: