Ir/serial connections and wiring – AMX NetLinx Integrated Controllers NI-3000 User Manual
Page 32

Connections and Wiring
26
NetLinx Integrated Controllers
IR/Serial Connections and Wiring
You can connect up to eight IR- or Serial-controllable devices to the IR/Serial connectors on the
rear of the NI-4000 and NI-3000 and up to four on the NI-2000 (FIG. 16). These connectors accept
an IR emitter (CC-NIRC) that mounts onto the device's IR window, or a mini-plug (CC-NSER) that
connects to the device's control jack. You can also connect a data 0 - 5 VDC device. These units
come with two CC-NIRC IR emitters (FG10-000-11).
The IR/Serial connector wiring specifications are listed in the following table.
I/O Port Wiring Specifications
NI-4000 and NI-3000
I/O Port Wiring Specifications NI-2000
Pin
Signal
Function
Pin
Signal
Function
1
GND
Signal GND
1
GND
Signal GND
2
I/O 1
Input/Output
2
I/O 1
Input/Output
3
I/O 2
Input/Output
3
I/O 2
Input/Output
4
I/O 3
Input/Output
4
I/O 3
Input/Output
5
I/O 4
Input/Output
5
12 VDC
PWR
6
I/O 5
Input/Output
7
I/O 6
Input/Output
8
I/O 7
Input/Output
9
I/O 8
Input/Output
10
12 VDC
PWR
FIG. 16 IR/SERIAL (male)
IR/Serial Connector Wiring Specifications
No.
NI-4000/3000 Port
NI-2000 Port
Signal
Function
1
9
5
GND (-)
Signal 1 (+)
2
10
6
GND (-)
Signal 2 (+)
3
11
7
GND (-)
Signal 3 (+)
4
12
8
GND (-)
Signal 4 (+)
5
13
N/A
GND (-)
Signal 5 (+)
6
14
N/A
GND (-)
Signal 6 (+)
7
15
N/A
GND (-)
Signal 7 (+)
8
16
N/A
GND (-)
Signal 8 (+)
IR / SERIAL (Ports 5-8)
IR / SERIAL (Ports 9-16)
8
7
6
4
5
3
2
1
4
2
3
1
NI-4000/NI-3000 IR/Serial connector
configuration (Port 9-16)
NI-2000 IR/Serial connector
configuration (Port 5-8)