beautypg.com

A.O. Smith 400A User Manual

Page 31

background image

3

*

PIPE RELIEF VALVE TO OPEN DRAIN.

N O T E : I F T E M P E R E D WAT E R I S

RECIRCULATED, RETURN LINE SHOULD

BE CONNECTED AT POINT “A”.

INSTALL IN ACCORDANCE WITH LOCAL

CODES.

TWO TEMPERATURE - ONE HEATER HIGH TEMPERATURE

WITH OR WITHOUT BUILDING RECIRCULATION

DANGER

TEMPERATURE SETTING SHOULD NOT EXCEED

SAFE TEMPERATURE AT FIXTURES. SEE WATER

TEMPERATURE CONTROL WARNING ON PAGE 3. IF

HIGHER PREHEAT TEMPERATURES ARE NECESSARY

TO OBTAIN ADEQUATE BOOSTER OUTPUT, ADD AN

ANTI-SCALD VALVE FOR HOT WATER SUPPLIED TO

FIXTURES.

CAUTION: IF BUILDING COLD WATER SUPPLY HAS A

BACK-FLOW PREVENTER, CHECK VALVE OR WATER

METER WITH CHECK VALVE PROVISIONS FOR

THERMAL EXPANSION OF WATER IN THE HOT WATER

SYSTEM MUST BE PROVIDED.

This manual is related to the following products: