To prevent damage, care must be taken not to apply too much torque

when attaching gas supply pipe to gas valve inlet.

Apply joint compounds (pipe dope) sparingly and only to the

male threads of pipe joints. Do not apply compound to the first

two threads. Use compounds resistant to the action of liquefied

petroleum gases.

DISCONNECT THE APPLIANCE AND ITS MANUAL GAS

SHUTOFF VALVE FROM THE GAS SUPPLY PIPING SYSTEM

DURING ANY SUPPLY PRESSURE TESTING EXCEEDING 1/2

PSIG (3.45Kpa). GAS SUPPLY LINE MUST BE CAPPED WHEN

DISCONNECTED FROM THE HEATER. FOR TEST PRESSURES

OF 1/2 PSIG (3.45Kpa) OR LESS, THE APPLIANCE NEED NOT

BE DISCONNECTED, BUT MUST BE ISOLATED FROM THE

SUPPLY PRESSURE TEST BY CLOSING THE MANUAL GAS

SHUTOFF VALVE.

BEFORE PLACING THE HEATER IN OPERATION, CHECK FOR

GAS LEAKAGE. USE SOAP AND WATER SOLUTION OR OTHER

MATERIAL ACCEPTABLE FOR THE PURPOSE OF LOCATING

GAS LEAKS. DO NOT USE MATCHES, CANDLES, FLAME OR

OTHER SOURCES OF IGNITION FOR THIS PURPOSE.

PURGING

Gas line purging is required with new piping or systems in which

air has entered.

CAUTION

PURGING SHOULD BE PERFORMED BY PERSONS EXPERIENCED

IN THIS TYPE OF GAS SERVICE. TO AVOID RISK OF FIRE OR

EXPLOSION, PURGE DISCHARGE MUST NOT ENTER CONFINED

AREAS OR SPACES WHERE IGNITION CAN OCCUR. THE AREA

MUST BE WELL VENTILATED AND ALL SOURCES OF IGNITION

MUST BE INACTIVATED OR REMOVED.

GAS METER SIZE - CITY GASES ONLY

Be sure that the gas meter has sufficient capacity to supply the full

rated gas input of the water heater as well as the requirements of

all other gas fired equipment supplied by the meter. If the gas meter

is too small, ask the gas company to install a larger meter having

adequate capacity.

GAS VALVES

WARNING

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL

TO SHUT OFF, TURN OFF THE MANUAL GAS CONTROL VALVE

TO THE APPLIANCE.

SYSTEM CONNECTIONS

The system installation must conform to these instructions and to

the local code authority having jurisdiction. Good practice requires

that all heavy piping be supported.

THERMOMETERS (Not Supplied)

Thermometers should be obtained and field installed as shown in

the installation diagrams.

Thermometers are installed in the system as a means of detecting

the temperature of the outlet water supply.

RELIEF VALVE

This heater is equipped with an approved temperature and pressure

relief valve. ASME ratings cover pressure relief. CSA ratings cover

release rate with temperature actuation.

FOR SAFE OPERATION OF THE WATER HEATER, THE RELIEF

VALVE(S) MUST NOT BE REMOVED OR PLUGGED.

In addition to the appliance relief valve, each remote storage tank

which may be used in conjunction with this appliance shall also be

installed with a properly sized, rated and approved temperature

(ANSI) and pressure (ASME) relief valve(s). This relief valve shall

comply with the standard for relief valves and automatic gas shutoff

devices for hot water supply systems. ANSI Z21.22-CSA 4.4.

Your local code authority may have other specific relief valve

requirements.

WARNING

THE PURPOSE OF A RELIEF VALVE IS TO AVOID EXCESSIVE

PRESSURE OR TEMPERATURE INTO THE STEAM RANGE,

WHICH MAY CAUSE SCALDING AT FIXTURES, TANK EXPLOSION,

SYSTEM OR HEATER DAMAGE. NO VALVE IS TO BE PLACED

BETWEEN THE RELIEF VALVE AND THE TANK.

A DRAIN LINE MUST BE CONNECTED TO THE RELIEF VALVE

TO DIRECT DISCHARGE TO A SAFE LOCATION TO AVOID

SCALDING OR WATER DAMAGE. THIS LINE MUST NOT BE

REDUCED FROM THE SIZE OF THE VALVE OUTLET AND MUST

NOT CONTAIN VALVES OR RESTRICTIONS, NOR SHOULD IT BE

LOCATED IN FREEZING AREAS. DO NOT THREAD OR CAP THE

END OF THIS LINE. RESTRICTED OR BLOCKED DISCHARGE

WILL DEFEAT THE PURPOSE OF THE VALVE AND IS UNSAFE.

THE DISCHARGE LINE SHALL BE INSTALLED TO ALLOW

COMPLETE DRAINAGE OF BOTH THE VALVE AND LINE.

WATER LINE CONNECTIONS

This manual provides detailed installation diagrams (see back

section of this manual) for typical methods of application for the

water heaters.

The water heater may be installed by itself, or with a separate storage

tank. When used with a separate storage tank, the circulation may be

either by gravity or by means of circulating pump. When a circulating

pump is used, it is important to note that the flow rate should be slow

so that there will be a minimum of turbulence inside the heater.

CLOSED SYSTEM

CAUTION

A closed system will exist if a check valve (without bypass), pressure

reducing valve (without bypass), or a water meter (without bypass) is

installed in the cold water line between the water heater and street

main (or well).

Excessive pressure may develop causing premature tank failure or

intermittent relief valve operation. This type of failure is not covered

by the limited warranty. An expansion tank or a similar device may

be required in the inlet supply line between the appliance and the

meter or valve to compensate for the thermal expansion of water

under supply pressure.

If a water heater is installed in a closed water system, check local