beautypg.com

Features in 275-03, Level 1, Level 2 – Allied Telesis AR700 Series User Manual

Page 21

background image

Features in 275-03

21

Version 275-05
C613-10473-00 REV D

Features in 275-03

Software Maintenance Version 275-03 includes all resolved issues and enhancements in earlier versions, and the resolved issues and enhancements in the
following tables. In the tables, for each product series:

“Y” in a white column indicates that the resolution is available in Version 275-03 for that product series.

“-” in a white column indicates that the issue did not apply to that product series.

a grey-shaded column indicates that Version 275-03 was not released on that product series.

Level 1

No level 1 issues

Level 2

CR

Module

Level

Description

AR

4

0

0

AR

7

x

5

A

R

75

0S

Ra

p

ie

r

i

A

T

-8

800

A

T

-8

600

A

T

-8

700

X

L

A

T

-8

948

A

T

-9

900

A

T

-9

800

CR00006827

IPv6

2

RIP routes with the same destination as one of the router or switch’s interface
routes were not being added correctly to the routing table.

This issue has been resolved.

Y

Y

Y

Y

Y

-

-

Y

Y

Y

CR00007844

IPv6

2

When MLD robustness, qinterval or qrinterval were set to non-default values,
the timeout values (or MA timers) of newly reported multicast address groups
were not updated to reflect these changed values. This issue was also recorded
as part of CR00011490.

This issue has been resolved.

Y

Y

Y

Y

Y

-

-

Y

Y

Y

CR00008046

PPP

2

Previously, if the switch was acting as a PPPoE access concentrator, it was
forwarding the first received ICMP Echo Request packet destined for a PPPoE
client back to the sender.

This has been resolved so the forwarding does not occur.

-

-

-

Y

Y

-

-

Y

Y

Y