Operation – Karcher BD 530 Bp User Manual
Page 24
– 6
Remove battery plug and join it to the
charging cable.
Connect the charger to the mains and
turn it on.
Add distilled water one hour before the
charging process comes to an end; fol-
low the correct acid level. There are
corresponding indicators on the battery.
ƽ
Danger
Danger of causticization!
–
Adding water to the battery in its dis-
charged state can cause the acid to
leak.
–
Use safety glasses while handling bat-
tery acid and follow the safety instruc-
tions to avoid personal injury or damage
to clothes.
–
Should the acid spray on to the skin or
clothes, rinse immediately with lots of
water.
Caution
Risk of damage!
–
Use only distilled or desalinated water
(EN 50272-T3) for filling the battery.
–
Do not add any substances (so-called
performance improving agents), else
warranty claims will not be entertained.
Batteries and chargers are available in spe-
cialised stores.
ṇ
Warning
Only use maintenance-free batteries while
replacing batteries in package appliances.
The charging status of the battery is shown
in the display on the operations panel:
–
After switching on the button for brush
operations or suction turbine, the oper-
ating hours are displayed for 5 seconds.
–
A bar diagram is then displayed to show
the charging status of the battery.
Switch off the button for brush opera-
tions and suction turbine
Release the lock screw for the contain-
er and open the container.
Clamp off the minus pole of the battery.
Clamp off the remaining cables from the
battery.
Remove the batteries.
Dispose of the used batteries according
to the local provisions.
Caution
Risk of damage. Raise the vacuum bar be-
fore reversing.
Note
The appliance is designed and built in such
a way that the brush head is projecting to-
wards the right. This enables working in a
comfortable way close to the edges.
Low maintenance batteries (wet batter-
ies)
Recommended batteries
Manufactur-
er, Kärcher
order no.
Description
DETA
6.654-097.0
12 V GIS 80, mainte-
nance-free, capacity: 80
Ah, voltage: 12 V
DETA
6.654-093.0
12 V GIS 75 DT, mainte-
nance-free, capacity: 75
Ah, voltage: 12 V
HOPPECK
E
6.654-224.0
12 V / 70 Ah, mainte-
nance-free, capacity: 70
Ah, voltage: 12 V
Recommended chargers
Manufactur-
er, Kärcher
order no.
Description
KÄRCHER
6.654-102.0
Separate charger for bat-
tery 6.654-093.0
KÄRCHER
6.654-067.0
Separate charger for bat-
tery 6.654-097.0
Battery control display
Removing the batteries
Operation
24