beautypg.com

Troubleshooting – Karcher HKF 50 E User Manual

Page 17

background image

English

17

ƽ

Danger

Risk of accident while working on the unit!
During all tasks:

Remove voltage from and secure high
pressure pump at the main switch.

Shut off the cleaning liquid supply.

Interior cleaners with electric drives:
Pull out the mains plug.

Interior cleaners with compressed air
drives: Shut off the compressed air sup-
ply.

Operator
Work designated with the sign “Opera-
tor” may only be carried out by persons
who have been instructed in the safe
operation and maintenance on the high
pressure plant.

Electricians
Only persons with a professional train-
ing in the electro-technical area.

Customer Service
Work designated with the sign “Custom-
er Service” may only be done by the fit-
ters of Kärcher Customer Service.

Maintenance schedule

Time

Activity

Performance

of whom

weekly or after 40 operat-
ing hours

Check the maintenance
unit for compressed air.

ƽ

Danger

Danger through compressed air. Shut off the compressed air
supply and let existing compressed air escape from the main-
tenance unit prior to performing maintenance work.
– Drain the water from the water separator by opening the

water drain screw, drain water and close water drain
screw.

– Fill the proportional oiler with suitable lubrication oil by un-

screwing the reservoir and filling it with lubricating oil.

– For oil type refer to following table.

Operator

monthly or after 160 oper-
ating hours

Check screws for tight fit.

Check that all screws are fitted tightly.

Operator

Lubricating oil for compressed air
maintenance unit (for HKF 50 P)

Festo spezial

Aral Vitam GF 32

Esso Nuto H 32

Mobil DTE 24

BP Energol HLP 32

Troubleshooting

Troubleshooting notes

Who may remedy faults?

This manual is related to the following products: