beautypg.com

Operation shutting down maintenance and care – Karcher HKF 50 E User Manual

Page 16

background image

16

English

ƽ

Danger

Risk of injury on account of the escaping
water jet that could be hot!
Only use the interior cleaner in closed

containers.

Only insert the interior cleaner into a

container or switch it into another con-
tainer while the separate high pressure
pump and internal drive are turned off.

Place interior cleaner onto container
and lock it.

Connect the high pressure pump to the
interior cleaner via a high pressure
hose.

Interior cleaners with electric drives:
Plug in the mains plug.

Interior cleaners with compressed air
drives: Open the compressed air sup-
ply.

Open the cleaning liquid supply.

Switch on the separate high pressure
pump.

Note
With almost all cleaning tasks, 2 nozzles
will achieve a good cleaning result. With
very large and extremely dirty containers, 1
nozzle is used; the other one is locked with
a screw.
Advantage:
– Better cleaning result by larger spray

width and impact force of the cleaning
jet.

Disadvantage:
– The bearings and seals are stressed

more and will wear faster.

– Extension of the cleaning time.

Note
Flush/rinse the interior cleaner for 30 sec-
onds prior to shutting it off. This will avoid
crusting and adhesion and thus a prema-
ture wear of the seals.

Switch off the separate high pressure
pump.

Shut off the cleaning liquid supply.

Interior cleaners with electric drives:
Pull out the mains plug.

Interior cleaners with compressed air
drives: Shut off the compressed air sup-
ply.

Remove the interior cleaner from the
container.

The basis for a safe operational plant is reg-
ular maintenance.
Use only original parts of the manufacturer
or part suggessted by him, such as
– replacement and wear parts
– Accessory parts
– Fuel
– Detergent

ƽ

Danger

Risk of accident while working on the unit!
During all tasks:

Remove voltage from and secure high
pressure pump at the main switch.

Shut off the cleaning liquid supply.

Interior cleaners with electric drives:
Pull out the mains plug.

Interior cleaners with compressed air
drives: Shut off the compressed air sup-
ply.

Operator
Work designated with the sign “Opera-
tor” may only be carried out by persons
who have been instructed in the safe
operation and maintenance on the high
pressure plant.

In order to guarantee a reliable operation og
the equipment, we success, you signed a
maintenance agreement. Please refer to
you local Kärcher service department.

Operation

Shutting down

Maintenance and care

Who may perform maintenance?

Maintenance contract