beautypg.com

Troubleshooting – Karcher HKF 200 ET User Manual

Page 33

background image

English

33

ƽ

Danger

Risk of accident while working on the unit!
During all tasks:

Remove voltage from and secure high
pressure pump at the main switch.

Shut off the cleaning liquid supply.

Interior cleaners with electric drives:
Pull the power cord or shut off power
supply.

Interior cleaners with compressed air
drives: Shut off the compressed air sup-
ply.

Operator
Work designated with the sign “Opera-
tor” may only be carried out by persons
who have been instructed in the safe
operation and maintenance on the high
pressure plant.

Electricians
Only persons with a professional train-
ing in the electro-technical area.

Customer Service
Work designated with the sign “Custom-
er Service” may only be done by the fit-
ters of Kärcher Customer Service.

Maintenance schedule

Time

Activity

Performance

of whom

weekly or after 40 operat-
ing hours

Check the maintenance
unit for compressed air.

ƽ

Danger

Danger through compressed air. Shut off the compressed air
supply and let existing compressed air escape from the main-
tenance unit prior to performing maintenance work.
– Drain the water from the water separator by opening the

water drain screw, drain water and close water drain
screw.

– Fill the proportional oiler with suitable lubrication oil by un-

screwing the reservoir and filling it with lubricating oil.

– For oil type refer to following table.

Operator

monthly or after 160 oper-
ating hours

Check screws for tight fit.

Check that all screws are fitted tightly.

Operator

Lubricating oil for compressed air
maintenance unit (for order nos.
3.631-016 and 3.631-036)

Festo spezial

Aral Vitam GF 32

Esso Nuto H 32

Mobil DTE 24

BP Energol HLP 32

Troubleshooting

Troubleshooting notes

Who may remedy faults?

This manual is related to the following products: