Troubleshooting – Karcher HKF 200 ET User Manual
Page 33
English
33
ƽ
Danger
Risk of accident while working on the unit!
During all tasks:
Remove voltage from and secure high
pressure pump at the main switch.
Shut off the cleaning liquid supply.
Interior cleaners with electric drives:
Pull the power cord or shut off power
supply.
Interior cleaners with compressed air
drives: Shut off the compressed air sup-
ply.
Operator
Work designated with the sign “Opera-
tor” may only be carried out by persons
who have been instructed in the safe
operation and maintenance on the high
pressure plant.
Electricians
Only persons with a professional train-
ing in the electro-technical area.
Customer Service
Work designated with the sign “Custom-
er Service” may only be done by the fit-
ters of Kärcher Customer Service.
Maintenance schedule
Time
Activity
Performance
of whom
weekly or after 40 operat-
ing hours
Check the maintenance
unit for compressed air.
ƽ
Danger
Danger through compressed air. Shut off the compressed air
supply and let existing compressed air escape from the main-
tenance unit prior to performing maintenance work.
– Drain the water from the water separator by opening the
water drain screw, drain water and close water drain
screw.
– Fill the proportional oiler with suitable lubrication oil by un-
screwing the reservoir and filling it with lubricating oil.
– For oil type refer to following table.
Operator
monthly or after 160 oper-
ating hours
Check screws for tight fit.
Check that all screws are fitted tightly.
Operator
Lubricating oil for compressed air
maintenance unit (for order nos.
3.631-016 and 3.631-036)
Festo spezial
Aral Vitam GF 32
Esso Nuto H 32
Mobil DTE 24
BP Energol HLP 32
Troubleshooting
Troubleshooting notes
Who may remedy faults?