Appendix, 1 flow chart, Air cooled version, standard – Karcher HD 7-250 De Tr1 User Manual
Page 85

Fliess.pm6.5 - GB
Page 5.1
Appendix
BOGE Operating instructions for CM 9 series screw compressor module
5.1
Flow chart
Air cooled version,
standard
1 = Suction filter
4 = Suction controller
5 = Air relief and regulation control valve
7 = Drive motor (on site)
8 = Air end
9 = Final compression temperature display and switch (on site)
10 = Combined compressed air/oil receiver
11 = Oil separator
12 = Safety valve
16 = Thermostatic oil control valve
17 = Oil cooler (on site)
18 = Oil filter
21 = Minimum pressure check valve
23 = Network pressure transmitter (on site)
24 = Pressure gauge reading in display (on site)
25 = Stop valve, compressed air outlet (on site)
27 = Stop valve, oil drainage
28 = Throttle with filter
M
1
4
5
7
8
9
10
11
12
15
16
17
18
21
23
I
24
14
25
27
28
15
Air IN
Compressed air
OUT