Sml installation information, Air connections, Air supply – A.J. Antunes & Co SML 8221210034 User Manual
Page 2

A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188
SML Installation Information
1-630-784-1000 Fax: 630-784-1651
Page 2 of 4
P/N 1011084 06/10
1-800-253-2991
Air Connections
Tubing recommended as minimums: 1/4” copper or alu-
minum tubing, or 1/8” pipe. All tubing and pipe must be
clean and free from oil, dirt, and chips. If piping runs over
five feet long, use a larger size tubing or pipe, and reduce
size at switch.
Air Supply
Should be connected as shown in the drawings below.
Always leave unused ports open to the atmosphere.
Standard Inlet Locations (1/8” NPT without
fittings)
Side inlets.
One side inlet and one
bottom machine thread
adapter with nut
(Specify 1-14 UNS).
Specify Other Inlet Locations
Negative
(Vacuum)
Inlet
Negative
(Vacuum)
Inlet
Positive
(Pressure)
Inlet
Positive
(Pressure)
Inlet
Vacuum
Connection
Pressure
Connection
High Vacuum or
(Low Pressure)
Low Vacuum or
(High Pressure)
PRESSURE ONLY
VACUUM ONLY
DIFFERENTIAL INLET CONNECTION