A.J. Antunes & Co TTD 815131004 User Manual
Ttd installation information, Specifications
A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188
Dimensions
Bracket and Screw Positions
Panel Cutout
Mounting Bracket and Screw
IMPORTANT
Please read these instructions carefully to assure
correct installation. This equipment must be
installed by a licensed electrician. Prior to being
put into operation, check all wiring and function of
the unit.
TTD Installation Information
Specifications
Sensor Type: Thermocouple (Type J or K)
NOTE: Ungrounded thermocouples are required when
multiple controllers/indicators are used or if the transform-
er is grounded.
Accuracy: 1% Full Scale ± LSD
Power: 12 VAC/DC (24 VAC, 115 VAC, 230 VAC with
remote transformer), 50/60 Hz.
Temperature Range: 50º to 990ºF (10ºC to 530ºC)
Ambient Operating Temperature: -30ºF to 140ºF
(-35ºF to 60ºC)
Ambient Storage Temperature: -40ºF to 180ºF
(-40ºF to 82ºC)
Connections: Terminal - Screw Terminal
Display: 3-Digit LED (0.56” Ht.)
Package: Panel Mount Epoxy Encapsulated
Shipping Weight: 1 lbs. (.45 kg)
1-630-784-1000 Fax: 630-784-1651
Page 1 of 4
P/N 1011093 06/10
1-800-253-2991
Panel Cut Out
2.82”
(72 mm)
1.13”
(29 mm)
2.80”
(71 mm)
3.10”
(79 mm)
1.40”
(36 mm)
0.38”
(10 mm)
2.0”
(51 mm)
1.10”
(28 mm)
NOTE: Dimensions are for reference only.
2.82”
1.13”