A.J. Antunes & Co SMR 8621204001 User Manual
Smr installation information, Dimensions inlet connections, Specifications

A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188
Dimensions
Inlet Connections
IMPORTANT
Please read these instructions carefully to assure
correct installation. This equipment must be
installed by a licensed electrician. Prior to being
put into operation, check all wiring and function of
the unit.
SMR Installation Information
Specifications
Electrical: 10A @ 125 VAC.; 8A @ 250 VAC.; 7A @ 277
VAC. (Resistive); 1/8HP @ 125 VAC; 1/4HP @ 250 VAC.
Pilot Duty, 125VA @ 125/277 VAC.
Max. Surge Pressure: 20” W.C.
Max. Ambient Temperature: 170°F (77°C)
Min. Ambient Temperature: -40°F (-40°C)
Shipping Weight: 1 lbs. (.45 kg)
Options:
1/4” Barb
1/4” Tube
1/4” Compression
1-630-784-1000 Fax: 630-784-1651
Page 1 of 2
P/N 1011098 06/10
1-800-253-2991
2 1/4”
(57 mm)
4 13/32”
(112 mm)
3 19/32”
(91 mm)
Mounting Hole
for #8 Screw
Standpipe With
Adjusting Screw
3”
Reset
Button
Note: Dimensions are
for reference only.
Reset
Button
1/2” Conduit
Knockout
Positive (Pressure) Inlet
Negative (Vacuum) Inlet