Tce installation information – A.J. Antunes & Co TCE 8253420060 User Manual

Page 3

background image

A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188

1-630-784-1000 Fax: 630-784-1651

Page 3 of 4

P/N 1011092 Rev. A 11/11

1-800-253-2991

TCE Installation Information

When the button on the lower left of the unit is pushed in

and held the set point is displayed. As long as the button

is held in the set point is displayed. When the button is

out the temperature at the thermocouple is displayed.
The knob on the lower right is used to change the set

point. Turn the knob clockwise to increase the set point.

Turn the knob counter clockwise to decrease the set

point.
The diagram above shows the output states of the

controller internal relay when the temperature, as seen by

the thermocouple, is above or below the set point. When

the relay is energized the decimal point following the least

significant digit (extreme right) will be illuminated. Make

connections accordingly, observing the power rating of

the contacts. If the thermocouple “opens” the internal

relay will go to its “not operated” state.

NC

C

NO

Temperature over

set point, relay not

operated

Temperature under set

point, relay operated

NC

C

NO

Set Point Calibration and Output States

Solid State Relay Output

When the temperature seen by the thermocouple is

above the set point, there will not be any voltage between

– and + terminals (pin 8 & 6). If the temperature seen

by the thermocouple is below the set point, there will be

12-16 VDC output. This output is capable of providing

30 mA. If an “open” thermocouple condition occurs, the

voltages between pins 8 & 6 will be zero.

Warranty

1. Antunes Controls products are guaranteed to be free

from mechanical and electrical defects for a period of

one year from date of shipment under normal use and

service provided installation is made in accordance

with manufacturers’ recommendations.

2. Parts deemed defective shall be repaired or replaced

at manufacturers option and at manufacturers expense

but shall not include foreign or federal excise taxes,

state or municipal sale or use taxes, all such taxes

not limited to the foregoing being responsibility of the

purchaser.

3. No charge for travel and/or mileage will be allowed to

purchaser.

4. Antunes Controls reserves the right to make changes

in design or make any improvements on any products.

The right is always reserved to modify our equipment

because of new technology, underwriter’s requirements

and/or government regulations.

5. The following are not covered under warranty:

a. Failure from neglect, abuse, careless handling and

mis-application of unit.

b. Failure to observe guidelines for installation or

improper voltage hook-up.

c. Failure caused by improper maintenance.

d. Unless specifically allowed by Antunes Controls, no

other charges may be included under warranty.

Limitation of Liability: If it is understood and agreed

that seller’s liability whether in contract, in tort, under

any warranty, in negligence or otherwise, shall not

exceed the return of the amount of the purchase price

paid by purchaser and under no circumstances shall

seller be liable for special, indirect or consequential

damages. The price stated for the equipment is a

consideration in limiting seller’s liability. No action,

regardless of form, arising out of the transactions may

be brought by purchaser more than one year after the

cause of action has accrued.

This manual is related to the following products: