AT-FS20x Series Installation Guide

25

When setting the DIP switches, consider the following:

ˆ

Setting the Auto Neg DIP switch for the twisted pair port to ON or OFF
enables or disables Auto-Negotiation for the port. If you disable Auto-
Negotiation, be sure to set the DIP switches for the port’s speed and
duplex mode to match the speed and duplex mode of the end-node.

ˆ

Disabling Auto-Negotiation on the twisted pair port also disables Auto
MDI/MDI-X and configures the port as MDI-X.

ˆ

For the fiber optic port, set the port’s duplex mode using the
appropriate Duplex Mode DIP switch. This setting must match the
duplex mode capability of the end-node to be connected to the port.

5. If you are installing the converter in an AT-MCR12 chassis, refer to

the AT-MCR12 Chassis Installation Guide from our web site for
instructions on how to install the converter in the chassis, then
proceed to Step 8.

6. Place the converter on a secure, level surface, leaving ample space

around the converter for ventilation.

7. Apply power to the converter.

2

1

Duplex
Mode

Up

Down

The fiber optic port operates in
half-duplex mode.
The fiber optic port operates in
full-duplex mode.

3

2

Duplex
Mode

Up

Down

The twisted pair port operates
in half-duplex mode.
The twisted pair port operates
in full-duplex mode.

4

2

Auto Neg

Up

Down

Auto-Negotiation on the twisted
pair port is OFF.
Auto-Negotiation on the twisted
pair port is ON.

Table 5. DIP Switch Settings (Continued)

DIP

Switch

No.

Port

Setting

Position

Description