Chapter 3, Troubleshooting, R 3: troubleshooting – Allied Telesis AT-GS924M User Manual
Page 49

49
Chapter 3
Troubleshooting
This chapter contains information on how to troubleshoot the switch if a
problem occurs.
Note
For further assistance, please contact Allied Telesis Technical
Supp
Problem 1: The POWER LED on the front of the switch is off.
Solutions: The unit is not receiving power. Try the following:
Verify that the power cord is securely connected to the power
source and to the AC connector on the back panel of the switch.
Verify that the power outlet has power by connecting another
device to it.
Try connecting the unit to another power source.
Try a different power cord.
Verify that the voltage from the power source is within the required
levels for your region.
Problem 2: A twisted-pair port on the switch is connected to a network
device, but the port’s Link Activity LED is off.
Solutions: The port is unable to establish a link to a network device. Try
the following:
Verify that the network device connected to the twisted-pair port is
powered on and is operating properly.
Verify that the twisted-pair cable is securely connected to the port
on the switch channel and to the port on the remote network
device.
Verify that the port is connected to the correct twisted-pair cable.
This is to eliminate the possibility that the port is connected to the
wrong network device, such as a powered-off device.
Try connecting another network device to the twisted-pair port with
a different cable. If the twisted-pair port is able to establish a link,
then the problem is with the cable or the other network device.
Verify that the twisted-pair cable does not exceed 100 meters (328
feet).