Acer Altos G901 User Manual
Page 192
Appendix B: System management
176
To set up paging alerts
To set up the server to send alerts as telephone pages:
1
Install an external modem on the Emergency Management Port
(COM2).
2
From the SSU Main window, choose Platform Event Manager
(PEM).
3
In the PEM window, click Configure EMP.
4
In the corresponding boxes, enter the following command strings
for the modem attached to the EMP port:
5
Click Save to save the changes.
6
Click Close to return to the PEM window.
7
In the PEM window, click Configure PEP.
8
Select the Enable PEP check box.
•
ESC Sequence
The escape sequence. This string is sent to
the modem before sending command strings.
The maximum length for the string is five
characters; longer strings are truncated.
•
Hangup String
The string to hang up or drop the
connection. The EMP automatically sends an
maximum length for the string is eight
characters; longer strings are truncated.
•
Modem Dial
Command
The command to dial a phone number. This
string is sent to the modem before sending
the paging string.
•
Modem Init
String
The initialization string for the modem. This
string is sent every time the EMP initializes.
The maximum length for the string is
determined at run-time from firmware. You
will be notified if the string is truncated.
Following a save, the actual string saved is
displayed in the edit box.