2 FAULTS/DIAGNOSTIC MENU
This is a list of the possible fault messages you may see displayed by the program-
mer. The messages are listed here in alphabetical order for easy reference.
ANTI-TIEDOWN
Mode Select 1 switch closed at startup
FIELD SHORT
Contactor coil or motor field winding shorted
CURRENT SHUNT FAULT
Current sensor error
EMR REV WIRING
Emergency reverse wiring check failed
FIELD OPEN
Motor field winding open
HPD
High pedal disable (HPD) activated
HW FAILSAFE
Hardware failsafe activated
LOW BATTERY VOLTAGE
Battery voltage too low
M- SHORTED
M- shorted to B-
MAIN CONT WELDED
Welded main contactor
MISSING CONTACTOR
Missing contactor
MOTOR HOT
Field winding resistance at disable setpoint
MOTOR WARM
Field winding resistance at cutback setpoint
NO KNOWN FAULTS
No known faults
OVERVOLTAGE
Battery voltage too high
SRO
Static return to off (SRO) activated
SRVC TOTAL
Total service timer expired
SRVC TRAC
Traction service timer expired
THERMAL CUTBACK
Cutback, due to over-/undertemperature
THROTTLE WIPER HI
Throttle wiper input too high
THROTTLE WIPER LO
Throttle wiper input too low
TOTAL DISABLED
Total disable timer expired
TRAC DISABLED
Traction disable timer expired
6 — PROGRAMMER MENUS: Faults/
Diagnostics Menu
- BCT-6200-6CA BCT-6000-6SA BCT-6000-6CA BCT-6250-6SA BCT-6250-6CA BC-620-6SA BC-620-6CA BC-600-6SA BC-600-6CA BC-625-6SA BC-625-6CA BC-620-4SA BC-620-4CA BC-600-4SA BC-600-4CA BC-625-4SA BC-625-4CA SCT-7750-6AC SCT-7750-6CA MV-520-6SA PCT-3510-6SA ST PCT-3510-6CA ST PCT-3510-6SA HB PCT-3510-6CA HB PCT-3500-6SA PCT-3500-6CA PC-300-6SA PC-300-6CA PC-325-4SA PC-325-4CA PC-300-4SA PC-300-4CA PMT-5000-6CA PMT-5000-6SA PMT-4500-6SA PMT-4500-6CA SC-775-6AC SC-775-6SA SC-775-6CA SC-750-4SA SC-750-4CA