Wesley BCT-6200-6SA User Manual
Page 66
Curtis 1243
GEN
2 Manual,
Rev. B
58
5 — VEHICLE PERFORMANCE ADJUSTMENT
2
Tuning the Controller to the Motor
The 1243
GEN
2 controller has the flexibility to be tuned to nearly any separately
excited motor from any manufacturer. The programmable parameters allow full
control of the motor’s maximum armature current during driving and braking
and full control of the motor’s maximum and minimum field current as well
as the field current relationship to the armature current. This flexibility allows
motor performance to be maximized while protecting it from operating outside
its safe commutation region.
In order to properly tune the controller, the following information should
be obtained from the motor manufacturer:
•
MAXIMUM
ARMATURE
CURRENT
RATING
•
MAXIMUM
FIELD
CURRENT
RATING
•
MINIMUM
FIELD
CURRENT
RATING
•
FIELD
RESISTANCE
,
HOT
AND
COLD
.
The performance of a separately excited motor changes depending on tem-
perature. This is due to the change in field winding resistance as the motor
heats up through use. When the field winding temperature increases, so does
its resistance; therefore, the maximum current that can be forced through the
winding is reduced. Reductions in the field current over the motor’s typical
operating temperature range can be 10% to 50%. Since the maximum avail-
able field current determines the maximum torque that can be produced by
the motor, the vehicle’s performance under load and up inclines will change as
the motor heats up. The change in performance can be limited by tuning the
motor when it is hot rather than cold. Therefore, it is recommended that the
following procedure be performed with a hot motor.
STEP
1. Using the programmer’s Program Menu, set the Drive Current
Limit parameter value in each mode to the smaller of: (a) the
motor’s peak armature current rating, or (b) the maximum
controller drive current limit. This value can later be adjusted
to establish the desired vehicle driving feel in each mode.
STEP
2. Set the Braking Current Limit parameter value in each mode to
the smaller of: (a) the maximum motor armature current rating,
or (b) the maximum controller braking current limit. This value
can later be adjusted to establish the desired vehicle braking feel
in each mode.
STEP
3. To set the Field Max parameter value, first decide whether you
want to maintain consistent vehicle operation throughout the
motor’s temperature range. If you do, proceed to Step 4. If,
however, maintaining operational consistency across motor
temperature is not a concern, but achieving maximum torque
is, proceed to Step 5.
STEP
4. For the most consistent operation across temperature, set the
Field Max parameter to the maximum field current available
- BCT-6200-6CA BCT-6000-6SA BCT-6000-6CA BCT-6250-6SA BCT-6250-6CA BC-620-6SA BC-620-6CA BC-600-6SA BC-600-6CA BC-625-6SA BC-625-6CA BC-620-4SA BC-620-4CA BC-600-4SA BC-600-4CA BC-625-4SA BC-625-4CA SCT-7750-6AC SCT-7750-6CA MV-520-6SA PCT-3510-6SA ST PCT-3510-6CA ST PCT-3510-6SA HB PCT-3510-6CA HB PCT-3500-6SA PCT-3500-6CA PC-300-6SA PC-300-6CA PC-325-4SA PC-325-4CA PC-300-4SA PC-300-4CA PMT-5000-6CA PMT-5000-6SA PMT-4500-6SA PMT-4500-6CA SC-775-6AC SC-775-6SA SC-775-6CA SC-750-4SA SC-750-4CA