2 — INSTALLATION & WIRING:
Controller
nuts required for the M8 bolts. The maximum bolt insertion depth below
the surface of the bus bar is 1.3 cm (1/2"). Bolt shafts exceeding this length
may damage the controller. The torque applied to the bolts should not exceed
16.3 N·m (12 ft-lbs).
Two 1/4" quick connect terminals (
S1
and
S2
) are provided for the con-
nections to the motor field winding.
WIRING: Standard Configuration
Figure 3 shows the typical wiring configuration for most applications. For
walkie applications the interlock switch is typically activated by the tiller,
and an emergency reverse switch on the tiller handle provides the emergency
reverse signal.
For rider applications the interlock switch is typically a seat switch or
a foot switch, and there is no emergency reverse.
Fig. 3
Standard wiring configuration, Curtis 1243
GEN
2 controller.
S1
S2
B-
M-
B+
INTERLOCK
5 k
Ω POT
THROTTLE
(TYPICAL)
EMERGENCY
REVERSE
emergency reverse wiring check (optional)
FORWARD
MAIN
CONTACTOR
COIL
POLARITY
PROTECTION
DIODE
REVERSE
MODE
SELECT
1
MODE
SELECT
2
ELECTRO-
MAGNETIC
BRAKE
KEY
SWITCH
POWER
FUSE
A
MAIN
CONTACTOR
B+
B-
A2
A1
S2
S1
CONTROL
FUSE
1
9
8
16
- BCT-6200-6CA BCT-6000-6SA BCT-6000-6CA BCT-6250-6SA BCT-6250-6CA BC-620-6SA BC-620-6CA BC-600-6SA BC-600-6CA BC-625-6SA BC-625-6CA BC-620-4SA BC-620-4CA BC-600-4SA BC-600-4CA BC-625-4SA BC-625-4CA SCT-7750-6AC SCT-7750-6CA MV-520-6SA PCT-3510-6SA ST PCT-3510-6CA ST PCT-3510-6SA HB PCT-3510-6CA HB PCT-3500-6SA PCT-3500-6CA PC-300-6SA PC-300-6CA PC-325-4SA PC-325-4CA PC-300-4SA PC-300-4CA PMT-5000-6CA PMT-5000-6SA PMT-4500-6SA PMT-4500-6CA SC-775-6AC SC-775-6SA SC-775-6CA SC-750-4SA SC-750-4CA