3 programmable parameters, Programmable parameters – Wesley BCT-6200-6SA User Manual
Page 27
![background image](/manuals/416185/27/background.png)
Curtis 1243
GEN
2 Manual,
Rev. B
19
3 — PROGRAMMABLE PARAMETERS
PROGRAMMABLE PARAMETERS
The 1243
GEN
2 controller has a number of parameters that can be programmed
using a Curtis programming device. These programmable parameters allow
the vehicle’s performance characteristics to be customized to fit the needs of
individual vehicles or vehicle applications.
The OEM can specify the default value for each parameter and can also
designate whether a parameter will have User or OEM access rights. Accordingly,
programmers are available in User and OEM versions. The User programmer
can adjust only those parameters with User access rights, whereas the OEM
programmer can adjust all the parameters. For information about Curtis pro-
gramming devices, see Appendix C.
The MultiMode™ feature of the 1243
GEN
2 controller allows operation in
four distinct modes. These modes can be programmed to provide four different
sets of operating characteristics, which can be useful for operating in different
conditions, such as slow precise indoor maneuvering in Mode 1; faster, long
distance, outdoor travel in Mode 4; and application-specific special conditions
in Modes 2 and 3. Eight parameters can be configured independently in each
of the four modes:
— acceleration rate (M1–M4)
— braking current limit (M1–M4)
— braking rate (M1–M4)
— deceleration rate (M1–M4)
— drive current limit (M1–M4)
— maximum forward speed (M1–M4)
— maximum reverse speed (M1–M4)
— restraint (M1–M4).
To better describe their interrelationships, the individual parameters are
grouped into categories as follows:
Battery Parameters
Acceleration Parameters
Braking Parameters
Interlock Braking Parameters
Electromagnetic Brake Parameters
Speed Parameters
Throttle Parameters
Field Parameters
Contactor Parameters
Sequencing Fault Parameters
Emergency Reverse Parameters
Motor Protection Parameters
Hourmeter Parameters
BDI Parameters
Fault Code Parameters
3
- BCT-6200-6CA BCT-6000-6SA BCT-6000-6CA BCT-6250-6SA BCT-6250-6CA BC-620-6SA BC-620-6CA BC-600-6SA BC-600-6CA BC-625-6SA BC-625-6CA BC-620-4SA BC-620-4CA BC-600-4SA BC-600-4CA BC-625-4SA BC-625-4CA SCT-7750-6AC SCT-7750-6CA MV-520-6SA PCT-3510-6SA ST PCT-3510-6CA ST PCT-3510-6SA HB PCT-3510-6CA HB PCT-3500-6SA PCT-3500-6CA PC-300-6SA PC-300-6CA PC-325-4SA PC-325-4CA PC-300-4SA PC-300-4CA PMT-5000-6CA PMT-5000-6SA PMT-4500-6SA PMT-4500-6CA SC-775-6AC SC-775-6SA SC-775-6CA SC-750-4SA SC-750-4CA