Example cr800 datalogger program for measuring a, Windsonic4, 12. wiring – Campbell Scientific WINDSONIC 2-D Sonic Wind Sensors User Manual
Page 29: Cr800 program example

WindSonic Two-Dimensional Sonic Anemometer
Totalize (1,one,diag<>NaN)
FieldNames ("no_data_TOT")
EndTable
BeginProg
one = 1
Scan (1,Sec)
SDI12Recorder (wind_direction,0R0!,1,0)
If (wind_direction = NAN ) Then
wind_speed = NAN
diag = NAN
EndIf
disable_flag = (wind_direction=NAN) OR (diag<>0)
CallTable stats
NextScan
EndProg
7.4.3 Example CR800 Datalogger Program for Measuring a WindSonic4
TABLE 7-12. Wiring for CR800 Program Example
Description Color
CR800
SDI-12 data
Green
C1
SDI-12 power
Red
+12 Vdc
SDI-12 reference
Black
G
shield Clear
G
'CR800 Series Datalogger
Public windsonic(3)
Alias windsonic(1) = wind_direction
Alias windsonic(2) = wind_speed
Alias windsonic(3) = diag
Units wind_direction = degrees
Units wind_speed = m/s
Units diag = unitless
Dim disable_flag AS Boolean
Dim one
Units one = samples
DataTable (stats,TRUE,-1)
DataInterval (0,30,Min,10)
WindVector (1,wind_speed,wind_direction,IEEE4,disable_flag,0,0,0)
FieldNames ("mean_wind_speed,mean_wind_direction,std_wind_dir")
Totalize (1,one,IEEE4,disable_flag)
FieldNames ("n_TOT")
Totalize (1,one,IEEE4,diag<>1)
FieldNames ("diag_1_TOT")
Totalize (1,one,IEEE4,diag<>2)
FieldNames ("diag_2_TOT")
Totalize (1,one,IEEE4,diag<>4)
FieldNames ("diag_4_TOT")
Totalize (1,one,IEEE4,diag<>8)
FieldNames ("diag_8_TOT")
Totalize (1,one,IEEE4,diag<>9)
FieldNames ("diag_9_TOT")
21