Installing EasyAG 50 probes

Copyright © 1991 – 2003 Sent ek Pt y Lt d All rights reserved

Page 17

3. Apply gentle pressure directly down onto the stabilization plate to force the pins into the ground.

Ensure that the stabilization plate pins remain parallel to one another.

4. Using

a

sledgehammer alternately beat the stabilization plate at the points provided to force it closer

to the ground. Do not beat continuously on any one side in advance of the other. The aim is to
achieve a situation where the pins are near parallel in the ground.

9

5. The

stabilization plate should be firm to the ground without causing significant soil compression

Warning

Do not compress the soil such that normal water infiltration into the soil is likely to

be inhibited. This is particularly important on clay soils.