1. Overview.......................................................................1

1.1 EC Sensor .................................................................................................1
1.2 A547 Interface ..........................................................................................1

2. Specifications ..............................................................2

2.1 CS547A Probe ..........................................................................................2
2.2 A547 Interface ..........................................................................................2
2.3 Temperature Sensor ..................................................................................3

3. Installation....................................................................3

3.1 Site Selection ............................................................................................3
3.2 Mounting ..................................................................................................3

4. Wiring............................................................................3

5. Programming ...............................................................4

5.1 Programming Overview............................................................................4
5.2 Example Measurement Programs .............................................................5

5.2.1 CRBasic ..........................................................................................5
5.2.2 Edlog...............................................................................................7

6. Calibration ..................................................................12

6.1 Conversion Factors .................................................................................12
6.2 Typical Ranges .......................................................................................12
6.3 Factory Calibration .................................................................................12
6.4 Field Calibration .....................................................................................12

6.4.1 CRBasic Calibration Program Example........................................13
6.4.2 Edlog Calibration Program Example ............................................13

7. Maintenance ...............................................................15

8. Analysis of Errors......................................................15

8.1 EC Measurement Error ...........................................................................15
8.2 Temperature Measurement Error............................................................17

9. Deriving a Temperature Compensation Coefficient.....18