Campbell Scientific CS125 Present Weather Sensor User Manual
Page 38
CS125 Present Weather Sensor
30
Example data returned by the GET command – See Section 12 for more
information on values returned by the `GET’ command
GET returned data
Example
Description
0x02
(1)
STX
Sensor ID
User Alarm 1 Set
User Alarm 1 Active
User Alarm 1 Distance
User Alarm 2 Set
User Alarm 2 Active
User Alarm 2 Distance
Serial Baud Rate
Sensor serial number (read only)
Visibility Units
Message interval
Polling Or Continuous modes
Message Format (Basic/Partial/Full)
RS232 or RS485 serial communications enabled
Averaging Period
Sample timing
Dew heater override
Hood heater override
Dirty window compensation
CRC checking on received commands
Sensor power down voltage 7.0
Relative humidity threshold
:
Delimiting character
XXXX
Checksum
:
Delimiting character
0x04
(1)
EOT
0x0D
(1)
Carriage return
0x0A
Line feed
(1) These values are shown in hexadecimal format not ASCII.
Example of a GET returned data
0 0 0 10000 0 0 10000 2 1009 M 30 0 2 1 1 1 0 0 0 1 11.5 D4FD
Explanation: -
Sensor ID = 0
User Alarm 1 not set
User Alarm 1 not active
User Alarm 1 distance = 10000 metres
User Alarm 2 not set
User Alarm 2 not active