beautypg.com

Environmental specifications, Mechanical specifications, Installation procedure – Campbell Scientific CS125 Present Weather Sensor User Manual

Page 13

background image

User Guide

5

Supported formats

RS232 (Full duplex only), default

RS485 (Half duplex)

8 bit data bytes

1 stop bit

Parity checking is not supported as most communication protocols used by
the CS125 have built in checksums as well as checks that communications
have been understood

5. Environmental specifications

Minimum

Value

Nominal

Value

Maximum

Value

Sensor temperature ranges

Operating temperature

-25°C

-

+60°C

Extended operating temperature

-40°C

-

+70°C

(1)

Storage temperature

-40°C

-

+85°C

Sensor humidity ranges

Operating humidity range

0%

-

100%

Sensor heater thresholds

Dew heater Turn On

-

<35°C

-

Dew heater Turn Off

-

>40°C

-

Hood heater Turn On

-

<5°C

-

Hood heater Turn Off

-

>15°C

-

(1) Extended temperature ranges are only guaranteed if the sensor has been tested by Campbell
Scientific and verified within this temperature range. Some degradation of absolute accuracy can be
expected at the extremes of the extended ranges.

6. Mechanical specifications

Main body including base mount

Height: 447 mm

Width: 640 mm

Depth: 245 mm

Sensor weight:

3 Kg

Sensor mounting: Bracket mounts on a vertical pole 32-52.5 mm diameter. The

mounting bracket has cut-outs for band clamps for larger
diameter masts.

Shipping weight: 6 Kg (including packing box)

7. Installation procedure

The CS125 measures environmental variables and is designed to be located in
harsh weather conditions. However there are a few considerations to take into
account if accurate and representative data from a site are to be obtained.