beautypg.com

1 the set command – Campbell Scientific CS125 Present Weather Sensor User Manual

Page 36

background image

CS125 Present Weather Sensor

28

14.1 The SET command

The set command is used to configure the CS125 via the command line. The SET
command is a single space delimited string that can be sent from any data logger
or PC equipped with an RS232 or RS485 port. The SET command and the
‘Device Configuration Utility’ software access identical settings within the
CS125, please refer to the ‘Device Configuration Utility’ section of this document
for a more detailed breakdown of the setting available here. This command is used
to change the default power up state of the sensor. See Section 14.2 if a setting is
going to be changed on a regular basis e.g. heater controls.

See Section 12 for more information on the values used by the `SET’ command.


SET transmitted data

Example

Description

0x02

(1)

STX ^B

(2)

:

Delimiting character

SET

SET

:

Delimiting character

0

Address based on Sensor ID

:

Delimiting character

Sensor ID

User Alarm 1 Set

User Alarm 1 Active

User Alarm 1 Distance

User Alarm 2 Set

User Alarm 2 Active

User Alarm 2 Distance

Serial Baud Rate

Sensor serial number (read only)

Visibility Units

Message interval

Polling Or Continuous modes

Message Format (Basic/Partial/Full)

RS232 or RS485 serial communications enabled

Averaging Period

Sample timing

Dew heater override

Hood heater override

Dirty window compensation

CRC checking on received commands

Sensor power down voltage

Relative humidity threshold

:

Delimiting character

XXXX

Checksum (use the valid CCITT checksum)

:

Delimiting character

0x03

(1)

ETX ^C

(2)

0x0D

(1)

Carriage return

0x0A

Line feed

(1) These values are shown in hexadecimal format not ASCII.
(2) As entered on a keypad.