Appendix B. Example Programs

BeginProg

Scan

(1,Sec,1,0)

'Measure the temperature

Therm109

(T109_C,1,1,Vx1,0,_60Hz,1.0,0.0)

'Call Data Table

CallTable

(Table1)

NextScan

EndProg

The following example can be used directly with CR6 series dataloggers.

'Program measures one 109 temperature probe once a second and
'stores the average temperature every 60 minutes.

'Wiring Diagram
'==============
' 109
' Probe
' Lead CR6
' Color Function Terminal
' ----- -------- ------
' Black Voltage-excitation input U10
' Red Analog-voltage output U1
' Purple Bridge-resistor ground Ground Symbol

' Clear Shield Ground Symbol

'Declare the variables for the temperature measurement

Public

T109_C

'Define a data table for 60 minute averages:

DataTable

(Table1,True,-1)

DataInterval

(0,60,Min,0)

Average

(1,T109_C,IEEE4,0)

EndTable

BeginProg

Scan

(1,Sec,1,0)

'Measure the temperature

Therm109

(T109_C,1,U1,U10,0,_60Hz,1.0,0.0)

'Call Data Table

CallTable

(Table1)

NextScan

EndProg

B-2