beautypg.com

Overview, Specifications – Campbell Scientific 109-L Temperature Probe User Manual

Page 12

background image

Model 109 Temperature Probe

7. Select any other sensors you have, and then finish the remaining Short Cut

steps to complete the program. The remaining steps are outlined in Short

Cut Help, which is accessed by clicking on

Help | Contents |

Programming Steps.

8. If LoggerNet, PC400, RTDAQ, or PC200W is running on your PC, and the

PC to datalogger connection is active, you can click

Finish in Short Cut

and you will be prompted to send the program just created to the

datalogger.

9. If the sensor is connected to the datalogger, as shown in the wiring

diagram in step 6, check the output of the sensor in the datalogger support

software data display to make sure it is making reasonable measurements.

5. Overview

The 109 is a rugged probe that accurately measures air, soil, or water

temperature in a variety of applications. The sensor consists of a thermistor

encapsulated in an epoxy-filled aluminum housing. This design allows the

probe to be buried or submerged in water to 15 m (50 ft) or 21 psi. When

measuring air temperature, a 41303-5A radiation shield is normally used to

mount the 109 and limit solar radiation loading. See Specifications for a

complete list of compatible dataloggers.

6. Specifications

Features:

Measures air, soil, or water temperature

Compatible with AM16/32-series multiplexers

Easy to install or remove

Durable

Compatible with the following CRBasic dataloggers: CR6,

CR200(X), and CR800 series, CR1000, CR3000, and CR5000

Sensor Element:

Measurement Specialties™ 10K3A1iA

thermistor

Survival Range:

–50° to 100 °C

Measurement Range:

–50° to 70 °C

Time Constant in Air:

30 to 60 s in a wind speed of 5 m/s

Maximum Cable Length:

1000 ft

Accuracy

1

Worst case:

±0.60 °C (–50 to 70 °C)

±

0.25 °C (–10 to 70 °C)

Interchangeability Error:

±

0.10 °C (0 to 70 °C)

±

0.13 °C at –10 °C

±

0.15 °C at –20 °C

±

0.18 °C at –30 °C

±

0.20 °C at –40 °C

±

0.50 °C at –50 °C

4