1.9 set remote addressing, Remote display address dip-switch settings, 1.9 set remote addressing -23 – PHASE RESEARCH 2000 Series User Manual
Page 91
PHASE RESEARCH
USER GUIDE
SECTION 13 - PARAMETERS PROGRAMMING
13-23
SECTION 13 - PARAMETERS
13-1.9 Set Remote Addressing
IF IT IS NECESSARY TO CHANGE A REMOTE DISPLAY’S ADDRESS,
USE THE FOLLOWING STEPS:
1. Unplug the five-pin connector from the top of the Remote Display and remove
the display from its mounting. Remove the two (2) smaller Phillips head
screws from the top of the Display first, and then remove the two (2) Phillips
head screws from the bottom of the Display. The two (2) covers of the Display
should now separate.
2. After separating the two covers, locate the eight (8) position dip-switch block
located on the upper right-hand side of the circuit board. Adjust the switches
according to the addresses you want.
Remote Display Address Dip-Switch Settings
3. Plug the connector back into the Remote Display and verify that it has the cor-
rect address before reassembling.
4. Once the Remote Display is addressed correctly, reassemble and remount it.
8
7
6
5
4
3
2
1
ON
Address 001:
Address 002:
Address 003:
Address 004:
Address 005:
Address 006:
Switch 1 ON, 2 OFF, 3 OFF
Switch 2 ON, 1 OFF, 3 OFF
Switches 1 & 2 ON, 3 OFF
Switch 3 ON, 1 OFF, 2 OFF
Switches 1 & 3 ON, 2 OFF
Switches 2 & 3 ON, 1 OFF
OFF