14

Operating Instructions Flytec 6005/6010

Sink Alarm, Speed and Temperature

The 6005/10 has a sink alarm that will alert the pilot if he/she is descending faster than a
predetermined threshold; an airspeed display with a stall alarm that will alert the pilot if
their airspeed falls below a predetermined threshold and a temperature display.

Overview



Key Direct

Functions

Set.Mode Option-Mode

1

2 3 4

5 6

Sink Alarm


Audio On/Off

Audio

Sink alarm

threshold

ST

Unit

TEMP

°C, °F

Corr

Temp

Sensor

-8.0 to

+7.9

Unit

Speed

km/h, kts,

mph

Stall

Stall-

speed

Corr

SPEED

speed

corretion

+/- 50%

SPEED

diSP

change
speed /

temp

display

Sink alarm

Press the Sink Alarm Key to switch the Sink Alarm

ON

or

OFF

The Sink Alarm icon will appear on the display when the

Sink Alarm is

ON

.






Set-Mode Sink Alarm

Press the Sink Alarm Key for three seconds to brings the
instrument into Sink Alarm Set-Mode. Use the Arrow Keys to
adjust the Sink Alarm Threshold between 40 and 2,000
ft/min.


Temperature Display

Without a speed sensor plugged into the 6005/10, the temp/speed display will show
ambient temperature. If a speed sensor is connected, then the display will alternate
between temperature and speed according to the interval set in the Option-Mode for the
Sink Alarm Key (option 6). Note: The temperature reading is delayed when there is a