Ice maker

Fault

Possible cause

Remedial action

Freezer compartment door

was open for a long time;

temperature is no longer

reached.

The evaporator (refrigeration

generator) in the NoFrost

system is covered in thick ice

and can no

longer be defrosted fully

automatically.

To defrost the evaporator, remove the frozen

food with the compartments, insulate well

and store in a cool location.
Switch off the appliance and move it away

from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins

to run into the evaporation pan,

at the rear of the appliance. Fig. '
To prevent the evaporation pan

from overflowing in this case,

mop up the condensation with a sponge.
The evaporator is defrosted when the water

stops running into the evaporation pan. Clean

the interior. Switch the appliance

back on again.

Appliance is not cooling,

temperature display and light

are lit.

Showroom mode is

switched on.

Hold down alarm button, Fig "/5, for

10 seconds until an acknowledgement signal

sounds.
After a short time check whether your

appliance is cooling.

Fault

Possible cause

Remedial action

The ice maker doesn’t work. Ice maker is not connected

to the power supply.

Call the customer service.

The ice maker is switched

off.

Switch on the ice maker (see “Ice maker”).

Ice maker is not receiving

any fresh water.

Ensure that the water has been connected

properly.

The freezer compartment

temperature is too warm.

Check freezer compartment temperature and,

if required, set slightly colder.

Supply hose is kinked or

crushed. Fig. (

Ensure that the supply hose is installed

correctly.