12.4
Set and Save Data Lock
Syntax
Hexadecimal
0xFE 0xCB 0xF5 0xA0 [level]
Decimal
254 203 245 160 [level]
Parameters
Parameter
Length
Description
level
1
Sets the data lock level
Description
This command will set and save the data lock level. See the Data Lock
section for more information.
Remembered
Always
Default
0
12.5
Dump the Filesystem
Syntax
Hexadecimal
0xFE 0x30
Decimal
254 48
ASCII
254 “0”
Description
This will allow you to dump the filesystem for debugging purposes. It
will return a 4 byte value LSB to MSB followed by 16384 bytes making
up the file system.
Remembered
No
12.6
Write Customer Data
Syntax
Hexadecimal
0xFE 0x34 [data]
Decimal
254 52 [data]
ASCII
254 “4” [data]
Parameters
Parameter
Length
Description
data
16
Writes the customer data
Description
Writes the customer Data. 16 Bytes of data can be saved in non-volatile
memory.
Remembered
No
12.7
Read Customer Data
Syntax
Hexadecimal
0xFE 0x35
Decimal
254 53
ASCII
254 “5”