Syntax
Hexadecimal
0xFE 0xB2 [Type] [refID]
Decimal
254 178 [Type] [refID]
Parameters
Parameter
Length
Description
Type
1
File type (0:Font File, 1:Bitmap)
refID
1
Reference ID number
Description
Download a specified file from the filesystem. The first 4 bytes will be
the length of the file (LSB to MSB) followed by 2 bytes representing the
width and height of the image then the data contained in the file.
Remembered
No
11.8
Moving a File
Syntax
Hexadecimal
0xFE 0xB4 [oldT] [oldID] [newT] [newID]
Decimal
254 180 [oldT] [oldID] [newT] [newID]
Parameters
Parameter
Length
Description
oldT
1
Old file type
oldID
1
Old file ID
newT
1
New file type
newID
1
New file ID
Description
This command can be used to move a file to a new file ID, or correct the
type of a file that was uploaded incorrectly. The command first checks
to see if there is a file identified by [oldT] and [oldID]. If it does exist,
and there is no file already with the desired type and ID, the ID and type
of the old file will be changed to [newT] and [newID] respectively.
Remembered
Always
12
Data Security
12.1
Introduction
Ensuring that your display’s exactly what you want it to can be the difference between a projects success
and failure. This is why we incorporate features such as Data Lock into the With this new feature you now
are in control over of how and when settings will be changed so there is no need to worry about the module
acting exactly like you expected it to because all the settings may be locked and remembered for the next
power up.
Matrix Orbital